CPSC Recalls

Recalls / 2006-11-30

Trane Recalls Air Conditioners after Incidents of Units Smoking

07508 · Recalled 2006-11-30 · CPSC page

Recalled Air Conditioner
Recalled Air Conditioner

Description

The recall includes 208-, 230- and 265-volt models of the Trane PTEE and PTHE Series Packaged Terminal Air Conditioners (PTACs). They were manufactured from about March 2006 through July 2006. The date code is F06C through F06G, and is written on the unit's Manufacturer's Data Plate located behind the molded plastic cover above the power connection. The units have the following model numbers, also written on the Manufacturer's Data Plate: PTEE0701UAA PTEE1501UAA PTHE0902UAA PTEE0702UAA PTEE1502UAA PTHE1201UAA PTEE0901UAA PTHE0701UAA PTHE1202UAA PTEE0902UAA PTHE0702UAA PTHE1501UAA PTEE1201UAA PTHE0901UAA PTHE1502UAA PTEE1202UAA

Hazards

The heating element on these commercially installed units can become displaced and, if it contacts metal, could short circuit. If the electric heater on one of those units short-circuits, wiring problems on 265-volt models could allow the unit to remain energized while the unit's fan is turned off, causing it to overheat and smoke.

Reported injuries

Individuals installing units observed smoking and smelled a burning odor in three units during installation testing procedures. No injuries have been reported.

Remedy

The power connectors are being rewired or replaced, and the heaters will be visually inspected and replaced as necessary in the 265-volt models. Although there have been no incidents with the 208-volt and 230-volt models, Trane is still inspecting these units as a precaution. Trane has contacted the affected customers directly.

Products

NameModelUnits
PTEE and PTHE Series Packaged Terminal Air Conditioners (PTACs)About 10,580

Parties

Manufacturer
Qingdao Haier Air Conditioner
Distributor
The Trane Co., of Piscataway, N.J.
Made in
China
Sold at
office buildings

Consumer contact

For more information, contact Trane at (800)235-2152 or at (931) 648-5047, between 9 a.m. and 4:30 p.m. ET Monday through Friday, or write an email to buddy.sholar@trane.com

Source: CPSC recall 07508. Inclusion in this database is not legal or medical advice.