Recalls / 2008-08-28
GIA Instruments Recalls Polariscopes Due to Shock Hazard
08603 · Recalled 2008-08-28 · CPSC page

Description
The recalled polariscopes are white in color with model number 415000 or 415 printed on the underside of the instrument. A polariscope is an instrument used by gemologists to assist in gem identification.
Hazards
The polariscopes can have a ground wire missing, posing a risk of electrical shock to the user.
Reported injuries
GIA has received four reports of consumers experiencing minor electric shock.
Remedy
Consumers should immediately stop using the recalled product and contact GIA Instruments to schedule a free retrofit of the Polariscope with a ground wire. GIA is notifying all consumers directly.
Products
| Name | Model | Units |
|---|---|---|
| Illuminator Polariscopes 415000 and 415 | About 8,000 |
Parties
- Manufacturer
- GIA Instruments
- Made in
- United States
- Sold at
- GIA schools, GIA's Web site, product catalogs, distributors, trade shows nationwide, $340.
Consumer contact
For additional information, contact GIA Instruments at (800) 421-8161 between 8 a.m. and 4 p.m. PT Monday through Friday or visit the firm's Web site at www.gia.edu
Source: CPSC recall 08603. Inclusion in this database is not legal or medical advice.